root@sysresccd ~]# smartctl -s on -a /dev/sda
smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.44-1-lts] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke,
www.smartmontools.org=== START OF INFORMATION SECTION ===
Model Family: Seagate Momentus 7200.5
Device Model: ST9750420AS
Serial Number: 5WS02JLD
LU WWN Device Id: 5 000c50 029e598be
Firmware Version: 0001SDM1
User Capacity: 750,156,374,016 bytes [750 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Wed Sep 9 13:31:15 2020 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF ENABLE/DISABLE COMMANDS SECTION ===
SMART Enabled.
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 121) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x73) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 153) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x103f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 088 087 006 Pre-fail Always - 218214885
3 Spin_Up_Time 0x0003 100 100 085 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 088 088 020 Old_age Always - 12634
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 11
7 Seek_Error_Rate 0x000f 082 060 030 Pre-fail Always - 195499546
9 Power_On_Hours 0x0032 094 094 000 Old_age Always - 6048
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 095 095 020 Old_age Always - 6126
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 1377
188 Command_Timeout 0x0032 100 096 000 Old_age Always - 10
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x0022 055 044 045 Old_age Always In_the_past 45 (Min/Max 45/45 #7)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 185
193 Load_Cycle_Count 0x0032 045 045 000 Old_age Always - 111460
194 Temperature_Celsius 0x0022 045 056 000 Old_age Always - 45 (0 9 0 0 0)
195 Hardware_ECC_Recovered 0x001a 119 099 000 Old_age Always - 218214885
197 Current_Pending_Sector 0x0012 085 085 000 Old_age Always - 312
198 Offline_Uncorrectable 0x0010 085 085 000 Old_age Offline - 312
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 5574 (77 202 0)
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 3487735662
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 2003149320
250 Read_Error_Retry_Rate 0x0000 100 001 000 Old_age Offline - 7
251 Unknown_Attribute 0x0000 100 001 000 Old_age Offline - 1
252 Unknown_Attribute 0x0000 100 001 000 Old_age Offline - 1
SMART Error Log Version: 1
ATA Error Count: 1378 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1378 occurred at disk power-on lifetime: 6047 hours (251 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 08 c0 00 Error: UNC at LBA = 0x00c00800 = 12584960
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 08 00 08 c0 40 00 00:02:37.122 READ FPDMA QUEUED
ef 10 03 00 00 00 a0 00 00:02:37.121 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 e0 00 00:02:37.121 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 00 00:02:37.120 IDENTIFY DEVICE
ef 90 03 00 00 00 a0 00 00:02:37.120 SET FEATURES [Disable SATA feature]
Error 1377 occurred at disk power-on lifetime: 6047 hours (251 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 08 c0 00 Error: UNC at LBA = 0x00c00800 = 12584960
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 08 00 08 c0 40 00 00:02:33.723 READ FPDMA QUEUED
60 00 00 f0 2a 00 40 00 00:02:33.722 READ FPDMA QUEUED
60 00 08 ff ff ff 4f 00 00:02:33.439 READ FPDMA QUEUED
60 00 08 ff ff ff 4f 00 00:02:33.434 READ FPDMA QUEUED
60 00 08 ff ff ff 4f 00 00:02:33.432 READ FPDMA QUEUED
Error 1376 occurred at disk power-on lifetime: 6047 hours (251 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 08 c0 00 Error: UNC at LBA = 0x00c00800 = 12584960
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 10 ff ff ff 4f 00 00:02:29.807 READ FPDMA QUEUED
60 00 08 ff ff ff 4f 00 00:02:29.801 READ FPDMA QUEUED
60 00 08 ff ff ff 4f 00 00:02:29.799 READ FPDMA QUEUED
60 00 08 ff ff ff 4f 00 00:02:29.792 READ FPDMA QUEUED
60 00 10 ff ff ff 4f 00 00:02:29.790 READ FPDMA QUEUED
Error 1375 occurred at disk power-on lifetime: 6047 hours (251 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 08 00 02 Error: UNC at LBA = 0x02000800 = 33556480
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 10 00 08 c0 4a 00 00:02:25.029 READ FPDMA QUEUED
60 00 08 80 08 80 4a 00 00:02:25.027 READ FPDMA QUEUED
60 00 10 80 08 00 46 00 00:02:25.024 READ FPDMA QUEUED
60 00 18 00 08 40 46 00 00:02:25.020 READ FPDMA QUEUED
60 00 08 80 08 40 46 00 00:02:25.014 READ FPDMA QUEUED
Error 1374 occurred at disk power-on lifetime: 6047 hours (251 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 08 40 04 Error: UNC at LBA = 0x04400800 = 71305216
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 18 00 08 80 46 00 00:02:21.357 READ FPDMA QUEUED
60 00 08 80 08 40 46 00 00:02:21.356 READ FPDMA QUEUED
60 00 18 00 08 40 46 00 00:02:21.351 READ FPDMA QUEUED
60 00 10 80 08 00 46 00 00:02:21.350 READ FPDMA QUEUED
60 00 18 00 08 00 46 00 00:02:20.950 READ FPDMA QUEUED
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed: read failure 90% 6048 12584960
# 2 Short offline Completed: read failure 90% 6048 12584960
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
[root@sysresccd ~]#